Shipment Advice Errors
The following errors may be encountered with the Shipment Advice message:
Data Element | Error Message | Description |
---|---|---|
SNDLAD | SNDLAD is required to build the process link key !!! | The error occurs if the source is empty or null. |
RCVLAD | RCVLAD is required to build the process link key !!! | The error occurs if the source is empty or null. |
E1EDT37 | GWEIT | Valid unit of measure required !!! | The error occurs if TARAG is present and greater than 0 but the source is not a valid value from the enumeration list. |
E1EDT37 | GWEIM | Valid unit of measure required !!! | The error occurs if BRGEW, NTGEW, or MAGEW are present and greater than 0, but the source is not a valid value from the enumeration list. |
E1EDT37 | VOLEM | Valid unit of measure required !!! | The error occurs if BTVOL, NTVOL, or MAVOL is present and greater than 0, but the source is not a valid value from the enumeration list. |
VRKME | Valid unit of measure required !!! | The error occurs if LFIMG are present and greater than 0, but the source is not a valid value from the enumeration list. |
GEWEI | Valid unit of measure required !!! | The error occurs if NTGEW or BRGEW is present and greater than 0, but the source is not a valid value from the enumeration list. |
VOLEH | Valid unit of measure required !!! | The error occurs if VOLUM is present and greater than 0, but the source is not a valid value from the enumeration list. |
E1EDL37 | GWEIT | Valid unit of measure required !!! | The error occurs if TARAG is present and greater than 0 but the source is not a valid value from the enumeration list. |
E1EDL37 | GWEIM | Valid unit of measure required !!! | The error occurs if BRGEW, NTGEW, or MAGEW are present and greater than 0, but the source is not a valid value from the enumeration list. |
E1EDL37 | VOLEM | Valid unit of measure required !!! | The error occurs if BTVOL, NTVOL, or MAVOL is present and greater than 0, but the source is not a valid value from the enumeration list. |
MEABM | Valid unit of measure required !!! | The error occurs if LAENG, BREIT, or HOEHE are present and greater than 0, but the source is not a valid value from the enumeration list. |
VEMEH | Valid unit of measure required !!! | The error occurs if VEMNG is present and greater than 0, but the source is not a valid value from the enumeration list. |
Class 2 Errors | ||
- | - | - |
Class 3 Errors | ||
The following is thrown for all Class 3 errors: “INTERNALERROR=Internal error from server [server details].” Please contact Support if this error is encountered. |